Danfoss - Industrial Refrigeration Controls

With more than 80 years of experience in the global refrigeration business, we develop and supply the right products for advanced, environmentally friendly cooling installations. With our wide range of components for Industrial Refrigeration Danfoss can deliver all valves for a project reducing complexity and optimizing project deliveries. 

No matter where or how you are involved in Industrial Refrigeration using Danfoss as your supplier offers you several benefits. 

Expansion Valves

Expansion Valves
  • Expansion Valves
Get Best Quote
Approx. Price: Rs 3,000 / UnitGet Latest Price
  • TEA thermostatic expansion valve, for ammonia
TEA thermostatic expansion valves are used for injection of refrigerant into evaporators.The valves are especially suitable for liquid injection in “dry” evaporators where the superheat at the evaporator outlet follows the evaporator load proportionally.
Assembled TEA valves for R717 for use in freezing and refrigeration systems, with rated capacities from 3.5 - 295 kW (1 - 85 tons TR). TEA has weld flange connections, exchangeable orifice and thermostatic element, and external pressure equalization. (1/4 in., ∅6.5 / ∅10 mm weld nipple, or 8 mm self-cutting union).
Max. bulb temperature = 100 °C.
Capillary tube length = 5 m.
Max. working pressure = 19 bar (275 psig).
Max. test pressure = 28.5 bar (415 psig).
Classified for: Fluid Group 1,
Category: Article 3, paragraph 3

  • TEAT, complete valves
TEAT desuperheating valves are used to inject refrigerant into the suction line of the refrigeration system to reduce the high discharge temperatures that can occur when the system operates with highly superheated suction vapour. TEAT valves are also used in two-stage refrigeration plants to control liquid injection into the intercooler and for temperature regulation of the medium, e.g. the temperature of the oil in a screw compressor.Refrigerants: HCFC, Non-flammable HFC refrigerants, and R717 (Ammonia).
P band = 20°C.
Capillary tube length = 5 m.
Max. bulb temperature = 150°C.
Max. working pressure = 20 bar.
Max. test pressure = 30 bar.
Classified for: Fluid Group 1,
Category: Article 3, paragraph 3
Request
Callback
Yes! I am interested

Electromechanical Pressure & Temperature Controls

Electromechanical Pressure & Temperature Controls
  • Electromechanical Pressure & Temperature Controls
Get Best Quote
The range of pressure switches and thermostats cover a lot of applications within refrigeration and air conditioning. The pressure switches and thermostats are in two categories: KP as standard and RT for heavy duty purposes. The switches can be delivered for fluorinated refrigerants as well as ammonia.

Product Ranges:
  • KP / KPU thermostats, standard applications
KP thermostats are single-pole, double-throw (SPDT) temperature operated electric switches. KP is used for regulation, but can also be seen in safety monitoring systems. It is here that the electronic mechanism shows its superiority. KP thermostats are available with vapour charge or with adsorption charge.
  • KP / KP-E / KPU / KP-A pressure switches, standard applications
KP pressure switches are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The switches are also used for starting and stopping refrigeration compressors and fans on air- cooled condensers.KP pressure switches are available in IP 30 and IP 44 enclosures.
  • RT thermostats / RT differential thermostats, heavy duty applications
RT thermostats are fitted with a single-pole changeover switch. The position of the contacts depends on the bulb temperature and the set scale value.The RT series includes thermostats for general applications within industrial and marine refrigeration.
  • RT differential pressure switches
The RT series includes differential pressure switches, pressure switches for neutral zone regulation and special pressure switches with gold-plated contact surface for PLC applications.The RT switches are for general applications within industrial and marine refrigeration.
  • MP / MP-A / MP-E differential pressure switches
MP 54 and MP 55 differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating oil pressure.If the oil pressure fails the differential pressure switch stops the compressor after a certain time period.
Request
Callback
Yes! I am interested

Pressure And Temperature Regulating Valves

Pressure And Temperature Regulating Valves
  • Pressure And Temperature Regulating Valves
Get Best Quote

Danfoss offers a wide range of pressure and temperature regulators for Industrial Refrigeration applications.

ICS, Servo Operated Valve: The ICS valve comprises three main components: a valve body, a function module and a top cover.
The pilot valves connected defines the function of the ICS valve. The max working pressure is 52 bar making the ICS valves suitable for CO2 and future high pressure refrigerants.

ICM, Motor Valve: The ICM motor valve comprises three main components: a valve body, a combined function module/top cover and an ICAD actuator. The max working pressure is 52 bar making the ICS valves suitable for CO2 and future high pressure refrigerants.

PM, Main Valve: PM valves are pilot operated main valves for regulating pressure and temperature in refrigeration systems.

The range also contains Pilot Valves, Oil Regulating Valves and Overflow Valves. The range also contains Liquid Distributors, Pilot Valves, Motorized Valves, Oil Regulating Valves and Overflow Valves.

Product Ranges:

  • ICS pilot operated servo valve
  • ICM motor operated valve
  • ICAD actuator, for ICM and ICMTS valves
  • ICV multifunction valves
  • ICV multifunction valves, accessories and spare parts
  • ORV temperature regulating valve, for oil regulation
  • OFV pressure regulating valves
  • PM pilot operated servo valve, pressure and temperature regulation
  • PMC pilot operated servo valve
  • EVM / CV, pilot valves/valve body for pressure and temperature regulating valves
Request
Callback
Yes! I am interested

Akva - Electric Expansion Valves For Ammonia

Akva - Electric Expansion Valves For Ammonia
  • Akva - Electric Expansion Valves For Ammonia
Get Best Quote
AKVA are electric expansion valves designed for ammonia refrigeration systems. The AKVA valves are usually controlled by an ADAP- KOOL® electronic controller.
The AKVA valves are supplied as a component programme, featuring:
• Separate valve
• Separate coil with terminal box or cable
• Spare parts in the form upper part, orifice and filter
The individual capacities are indicated with a number forming part of the type designation. The number represents the size of the orifice of the valve in question.
A valve with orifice 3 wille.g. be designated AKVA 10-3.
The orifice assembly is exchangeable.
• Refrigerants: R744, R717, R22/R407C, R404A/R507, R410A, R134a, R407A, R23. For other refrigerants, please contact Danfoss.
• The valve requires no adjustment.
• Wide regulation range.
• Replaceable orifice assembly.
• In some applications AKVA can be used both as expansion valve and solenoid valve.
• Wide range of coils for d.c. and a.c.

Models: 
  • AKVA 10
Tolerance of coil voltage: +10 / –15%.
Enclosure to IEC 529: Max. IP 67.
Working principle: PWM ( Pulse-width modulation).
Recommend period of time: 6 seconds.
Capacity (R717): 4- 100 kW.
Regulation range: 10 - 100%.
Connection type: Weld.
Media temperature: -50- +60°C.
Ambient temperature: -50- +50 °C.
Leak of valve seat: <0.02% of Kv value.
MOPD: 18 bar.
Filter: Internal 100 µm replaceable.
Max. working pressure: 42 bar g. 

  • AKVA 15 
Tolerance of coil voltage: +10 / –15%.
Enclosure to IEC 529: Max. IP 67.
Working principle: PWM ( Pulse-width modulation).
Recommend period of time: 6 seconds.
Capacity (R717): 125- 500 kW.
Regulation range: 10 - 100%.
Connection type: Weld. Media temperature: -40- +60°C.
Ambient temperature: -40- +50 °C.
Leak of valve seat: <0.02% of kv-value.
MOPD: 22 bar.Filter: External 100 µm.
Max. working pressure: 42 bar g.

  • AKVA 20 
Tolerance of coil voltage: +10 / –15%.
Enclosure to IEC 529: Max. IP 67.
Working principle: PWM ( Pulse-width modulation).
Recommend period of time: 6 seconds.
Capacity (R717): 500- 3150 kW.
Regulation range: 10 - 100%.
Connection type: Weld.
Media temperature: -40- +60°C.
Ambient temperature: -40- +50°C.
Leak of valve seat: <0.02% of Kv value. MOPD: 18 bar.
Filter: External 100 µm. Max. working pressure: 42 bar g.
Request
Callback
Yes! I am interested

Electronic Controller

Electronic Controller
  • Electronic Controller
Get Best Quote
Product Range:
  • EKC 347
EKC 347 liquid level controller is used for regulation of the refrigerant level in:
• Pump reservoirs
• Separators
• Intermediate coolers
• Economisers
• Condensers
• Receivers
• Liquid level control
• Alarm if the set alarm limits are exceeded
• Relay outputs for upper and lower level limits and for alarm level
• Analog input signal which can displace the reference
  • EKC 366 
The module is an interface unit for control of an evaporating pressure valve.The media temperature is regulated by a PLC or similar device.The interface module receives a variable signal from the PLC and subsequently regulates the valve, so that the refrigeration is as accurate as possible.The controller is used for regulating a valve in a refrigerating system -
for example in connection with:
• Long-term storage of fruits and vegetables
• Refrigerating plants
• Brewery systems
• Processing plants Temperature sensors = Type AKS (Pt 1000)
  • EKC 319A, liquid injection in the suction line 
EKC 319A Controller limits the pressure gas temperature by opening up for liquid injection in the suction line. A temperature sensor registers the pressure gas temperature.If the temperature reaches the set temperature value, valve opening is commenced. A PI regulation adapts the opening degree of the valve in order to keep the temperatures at acceptable levels.
  • EKE 347, Liquid level controller 

  • Liquid level control.
  • Alarm if the set alarm limits are exceeded.
  • Relay outputs for upper and lower level limits and for alarm level.
  • User friendly and easy setup Wizard for first time configuration.
  • PI control.
  • Low or High side control.
  • When AKV/A is selected, a MASTER/SLAVE system can run up to 3 AKV/A with distributed Opening Degree.
  • Manual control of output.
  • Limitation of Opening degree possible.
  • ON/OFF operation with hysteresis.
  • Programming menu with 3 access levels and separate passwords.
  • Connection to other EKE347 controllers possible.
  • Wired remote display possible.
  • BUS connection for external data transfer.

  • EKC 361
The controller and valve can be used where there are stringent requirements to accurate temperature control in connection with refrigeration, e.g.:
 • Cold room for fruits and food products.
 • Refrigerating systems.
• Work premises in the food industry.
 • Process cooling of liquids. Temperature sensor = Type AKS (Pt 1000 ohm).
  • EKC 315A
The controller and valve can be used where there are requirements of accurate control for superheat and temperature in connection with refrigeration.
Expansion valve = type TQ / AKV/ ICM / MEV.
Temperature sensor = type AKS (Pt1000).
Pressure transmitter = type AKS 33 (4-20 mA).
  • EKC 331/T 
EKC 331 controllers are used for capacity regulation of compressors or condensers in small refrigerating systems based on pressure input. It can also be used as an extension relay module with the EKC531
Temperature sensors= AKS(Pt1000)
Pressure transmitters = AKS32R or AKS33
Display= EKA 

    Request
    Callback
    Yes! I am interested

    Water Level Controller Machine

    Water Level Controller Machine
    • Water Level Controller Machine
    • Water Level Controller Machine
    • Water Level Controller Machine
    Get Best Quote
    Product Ranges:
    • HFI float valves, high pressure
    HFI is a float valve for high pressure with internal liquid measuring device. The float valve is designed for direct flange mounting or welding on to plate heat exchanger type condensers. HFI is direct acting, and consequently no differential pressure is required to activate the valve. Owing to its simple design HFI is sturdy and reliable. The float valve is equipped with a purge valve for purging non-condensable gases
    • SV 4 - SV 6 float valve, for low pressure side
    SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia (R717) and other common types of refrigerants.
    • PMFH / PMFHE liquid level regulating valve, for the condenser side, controlled by SV
    Refrigerants: HCFC, HFC, and R717. Max. working pressure: 28 bar. Media temperature: -60 °C - 120 °C. Housing material: Low temperature cast iron, EN-GJS-400-18-LT. Delivered with flange gaskets/bolts, blanking plug and pilot connection.
    • AKS 38 liquid level switch
    AKS 38 is an electro-mechanical liquid level switch designed to provide a reliable, electro-mechanical response to liquid level changes. AKS 38 can control liquid level in vessels and accumulators or can be used as a low/high level safety alarm. For the control and detection of liquid levels in:• Liquid over-feed accumulators. • Flooded surge drums. • Flooded shell and tube chillers. • High and low pressure receivers. • Intercoolers. • Use as low/high level safety switch to protect circulating pumps/compressors.
    • LLG sight glass 
    LLG are sight glasses in ductile steel and meet the strictest requirements on industrial and marine refrigeration installations. The sight glasses are offered in 3 different versions: 
    - with welding nipples (LLG). 
    - with stop valves equipped with caps (LLG S). 
    - with stop valves and sight adapter in acrylic glass ready for insulation on site (LLG SF). 

    • SV 1 / SV 3 float valve, for PMFL/PMFH 
    Typically the SV 1 and 3 float valves are used as float pilot valves for the main expansion valves type PMFL or PMFH. SV 1 and 3 can also be used separately for modulating liquid level regulation in refrigerating, freezing and air conditioning systems with ammonia or fluorinated refrigerants.
    • PMFL / PMFLE liquid level regulating valve for the evaporator side, controlled by SV 
    Refrigerants: HCFC, HFC, and R717. 
    Max. working pressure: 28 bar. 
    Media temperature: -60 °C - +120 °C. 
    Housing material: Low temperature cast iron, EN-GJS-400-18-LT. 
    Delivered with flange gaskets/bolts, blanking plug and pilot connection.
    • RT 280A / 281A liquid level switch, liquid level alarm, safety switch, liquid level regulator 
    RT 280A and 281A are primarily used as liquid level alarms and safety switches to prevent too high a liquid level in liquid separators.Secondarily, RT 280A and 281A can be used as liquid level regulators where a liquid level differential of up to 40 mm is permitted. RT 280A and 281A used as safety switches to ensure that the max. permissible refrigerant level in flooded evaporators, pump tanks or liquid separators is not exceeded. As liquid level regulators, RT 280A and 281A maintain a constant average refrigerant level in flooded evaporators, pump tanks or liquid separators.
    • AKS 4100 / AKS 4100U liquid level sensor 
    The AKS 4100 / AKS 4100U liquid level sensor is designed specifically to measure refrigerant liquid levels in a wide range of refrigeration applications, in vessels, accumulators, receivers, standpipes, etc. 
    Request
    Callback
    Yes! I am interested

    Electronic Sensors & Transmitters

    Electronic Sensors & Transmitters
    • Electronic Sensors & Transmitters
    • Electronic Sensors & Transmitters
    • Electronic Sensors & Transmitters
    Get Best Quote
    • AKS 11, PT1000 Temperature Sensor, Superheat Measurement
    Surface and duct sensor. The sensors are adjusted and meet the tolerance requirements of DIN IEC 751 class B. Temperature range: –50 - 100°C. Enclosure: IP 67. Connection: PVC cable, 2 x 0.2 mm2 Industrial Pack: price quoted in price list is per unit

    • AKS 21, Multi-purpose Sensor/Surface Sensor/Immersion Senso
    Robust temperature sensor with large temperature range. Developed for use in demanding industrial applications. AKS 21 is based on a PT element with a resistance of 1000 ohm at 0°C.The sensors are adjusted and comply with the requirements to tolerance in DIN IEC 751, class B.

    • AKS, pressure transmitters
    AKS pressure transmitters are designed for precise and energy optimized control.
    The robust design makes AKS suitable for a wide range of applications, such as:
    -Air conditioning systems
    -Refrigeration plants
    -Process control applications
    -Laboratory applications
    Product range:
    4 - 20 mA (AKS 33, AKS 3000)
    1 - 5 V DC, 1 - 6 V DC, 0 - 10 V DC (AKS 32)
    10 - 90% ratiometric output (AKS 32R) Highly developed sensor technology means high pressure regulation accuracy, a very important factor in the precise and energy-economic capacity regulation of refrigeration plants.
    • Temperature compensation for LP and HP pressure transmitters, developed specially for refrigeration plants: LP: –30 - 40°C (16 bar) HP: 0 - 80° (>16 bar)
    • Compatibility with all refrigerants incl. ammonia means less stock and greater application flexibility.
    • Effective protection against moisture means that the sensor can be mounted in very harsh environments, e.g. in the suction line encapsulated in an ice block.
    • Robust construction gives protection against mechanical influences such as shock, vibration and pressure surge.
    • No adjustment necessary. With the highly developed sensor technology and sealed gauge principle, the accuracy of the factory setting is maintained independent of variations in ambient temperature and atmospheric pressure. This is very important when ensuring evaporating pressure control in air conditioning and refrigeration applications.
    • Built-in voltage stabiliser
    • EMC protection according to EU EMC-directive (CE-marked)
    • UL approved

    • AKS 12, PT 1000 Temperature Sensor
    Air temperature sensor with average temperature range and average time constant. The sensor is based on a PT element with a resistance of 1000 ohm at 0°C.Temperature range: -40 - 80°C.Enclosure: IP 67.Connection: PVC cable, 2 x 0.22 mm2.The sensorsare adjusted and comply with the requirements to tolerance in DIN IEC 751, class B. Industrial Pack: price quoted in price list is per unit

    • AK-HS 1000 HACCP Temperature sensor
    AK-HS 1000 temperature sensor is intended for temperature monitoring and data logging in HACCP systems. It is designed to simulate a product located in a refrigeration appliance. This results in realistic HACCP data. In combination with an ADAP-KOOL® appliance controller, the HACCP tolerance requirement of ±1 K in the entire area can be fulfilled over the full range of -30°C to 15°C.

    • AKS 2050, ratiometric output signal
    AKS 2050 is resistant to cavitation, liquid hammer and pressure peaks and is designed for use in demanding A/C and refrigeration environments, with high vibration stability and all wetted parts and enclosure of acid resistant steel (AISI 316L). Temperature compensated, linearized and laser calibrated.Ratiometric output signal: 10-90% of supply voltage.Electrical connection: DIN 43650-A, PLUG PG9Pressure connection: M16 x 1.5 Ermeto.
    Request
    Callback
    Yes! I am interested

    Safety Valves

    Safety Valves
    • Safety Valves
    Get Best Quote
    Approx. Price: Rs 12,000 / UnitGet Latest Price
    The valves are especially designed for protection of components against excessive pressure and to meet the strict quality demands and safety requirements for industrial refrigeration installations, specified by international classification societies.

    Product Ranges:
    • SFA safety relief valves, back pressure dependent
    SFA 15 are safety relief valves - back pressure dependent - in angleway execution, specially designed for protection of vessels and other components against excessive pressure.
    The valve is designed to meet the strict quality demands and safety requirements for refrigeration installations, specified by the international classification societies.
    The valve is recommended as an external and internal safety relief valve in refrigeration plants. The spring housing is closed tightly to avoid refrigerant leakage.
    The valves can be delivered with set pressures between 10 and 40 bar g (145 and 580 psi g).
    Standard pressure setting valves having "TÜV Pressure Setting Certificate" with each valve, are also available.

    • SFV safety relief valves, back pressure dependent
    SFV 20 - 25 are safety relief valves - back pressure dependent - in angleway execution, specially designed for protection of vessels and other components against excessive pressure.
    The valve is designed to meet the strict quality demands and safety requirements for industrial refrigeration installations, specified by the international classification societies.
    The valve is recommended as an external and internal safety relief valve in refrigeration plants. The spring housing is closed tightly to avoid refrigerant leakage.
    The inlet flow diameters of the valves are:
    - 18 mm (3/4 in.) for SFV 20, and
    - 23 mm (1 in.) for SFV 25.
    The valves can be delivered with set pressures between 10 and 25 bar g (145 and 363 psi g).
    Standard pressure setting valves having "TÜV Pressure Setting Certificate" with each valve, are also available.

    • BSV safety relief valves, back pressure independent
    BSV 8 is a safety relief valve - back pressure independent, designed for protection of small components against excessive pressure.
    BSV 8 is an angleway valve that can operate with a very high back pressure. It is designed to meet the strict quality demands and safety requirements for refrigeration installations as specified by the international classification societies.
    As the valve is back pressure independent, it is recommended for use as an internal safety relief valve. However, it can also be used as an external safety valve. The spring housing is tightly sealed to avoid refrigerant leakage.
    The inlet flow diameter of the BSV 8 is 8.0 mm (5/16 in.).
    BSV 8 is available with set pressures between 10 and 25 bar g (145-363 psi g), and also with individually assigned ”TÜV pressure setting Certificate”.

    • POV safey relief valve, pilot operated
    POV safety relief valve is used in conjunction with the BSV back pressure independent safety valve and is specifically designed for protecting compressors against excessive pressure.

    • DSV change-over valve 
    DSV are 3-way valves designed specifically for use with double safety valve systems, but are also suitable for other purposes. The valves are equipped with threads for nipple/flange connection for easy inspection or replacement of safety valves.
    DSV are designed to meet the strict quality demands on industrial refrigeration installations specified by the international classification societies.
    DSV valves are carefully designed to establish favourable flow conditions. The valve cone is designed to ensure perfect closing. Even a light tightening of the valve will close the valve effectively. All valves are equipped with vented cap
    Request
    Callback
    Yes! I am interested

    Line Components

    Line Components
    • Line Components
    Get Best Quote
    Approx. Price: Rs 10,000 / PieceGet Latest Price
    The Line Components product range includes filters and strainers, stop check valves and check valves for use in refrigeration and air conditioning plantswith ammonia (R717) as refrigerant. The filters are used in front of automatic controls, pumps, compressors etc. for initial plant start-up and where permanent filtration of the refrigerant is required. The filters reduce the risk of undesirable system breakdowns and reduce wear and tear on plant components.

    • SVL multifunction valve
    SVL multifunction valve body, made from low-temperature resistant cast steel and suitable for a maximum working pressure of 52 bar, is welded or soldered into the pipes to create a fully hermetic coupling. The valve body will never have to be replaced, because it does not suffer any wear. All products in the SVL platform can be used with all commonly used refrigerants incl. HFC and HCFCs.
    The backbone of the SVL platform is the common valve housing, which is available in angleway or straightway execution.
    The complete top parts offer five different functions: Stop valves SVA-S and SVA-L, Regulating valves REG-SA and REG-SB, Stop/Check valves SCA-X, Check valves CHV-X and Filters FIA. All five complete top parts fit the same housing and they all have the same high specification making selection, system design and mounting simple and trouble free.

    • NRVS check valve
    Check valve type NRVS is for use in liquid line applications. NRVS is designed to be mounted directly to PM or solenoid valves EVRA/EVRAT. SVL multifunction valve body, made from low-temperature resistant cast steel and suitable for a maximum working pressure of 52 bar, is welded or soldered into the pipes to create a fully hermetic coupling. The valve body will never have to be replaced, because it does not suffer any wear. All products in the SVL platform can be used with all commonly used refrigerants incl. HFC and HCFCs.
    The backbone of the SVL platform is the common valve housing, which is available in angleway or straightway execution.

    • NRVA check valve, for ammonia and fluorinated refrigerants
    Check valve type NRVA can be used in liquid, suction and hot gas lines in refrigeration and air conditioning plants with ammonia. NRVA can also be used in refrigeration systems with fluorinated refrigerants.When NRVA is used in liquid lines where cold thick oil or impurities may be present, it is recommended that the standard spring be replaced by a special spring.

    • SCA-X 15-125 check & stop valve (SVL product range)
    SCA-X are check and stop valves with built-in stop valve function. SCA-X valves are available in angleway versions. The valves are designed to open at very low differential pressures, allow favourable flow conditions and are easy to disassemble for inspection and service. SCA-X valves are equipped with vented cap and have internal backseating enabling the spindle seal to be replaced whilst the valve is still under pressure. Laser cut V-ports provide excellent opening characteristics (SCA-X 50-125). The valve cone has a built-in flexibility to ensure a precise and tight closing towards the valve seat.

    • SCA-X SS check & stop valve, in stainless steel (SVL product range)
    SCA-X SS are check and stop valves in stainless steel with a built-in stop valve function. SCA-X SS are available in angleway versions. The valves are designed to open at very low differential pressures, allow favourable flow conditions and are easy to disassemble for inspection and service. SCA-X are equipped with vented cap and have internal backseating enabling the spindle seal to be replaced whilst the valve still under pressure. The valve cone has a built-in flexibility to ensure a precise and tight closing towards the valve seat.
    Request
    Callback
    Yes! I am interested

    Line Components

    Line Components
    • Line Components
    Get Best Quote
    • CHV-X 15-125 check valves (SVL product range)
    CHV-X check valves are available in angleway versions. The valves are designed to open at very low differential pressures, allow favourable flow conditions and are easy to disassemble for inspection and service. Laser cut V-ports provide excellent opening characteristics (CHV-X 50-125). The valve cone has a built-in flexibility to ensure a precise and tight closing towards the valve seat.

    • CHV-X SS check valves, in stainless steel (SVL product range)
    CHV-X SS stainless steel check valves are available in angleway versions. The valves are designed to open at very low differential pressures, allow favourable flow conditions and are easy to disassemble for inspection and service. The valve cone has a built-in flexibility to ensure a precise and tight closing towards the valve seat.

    • FA strainer, non welded
    Strainer type FA with interchangeable filter insert is used in lines carrying fluorinated refrigerants, ammonia, water, brine, oil, and gas.

    • FIA 15-200 strainer (SVL product range)
    FIA are a range of angleway and straightway strainers, which are carefully designed to give favourable flow conditions. The design makes the strainer easy to install, and ensures quick strainer inspection and cleaning. FIA strainers are used ahead of automatic controls, pumps, compressors etc., for initial plant start-up and where permanent filtration of the refrigerant is required.The strainer reduces the risk of undesirable system breakdowns and reduces wear and tear on plant components.

    • FIA-SS strainer, in stainless steel (SVL product range)
    FIA SS are a range of stainless steel angleway and straightway strainers, which are carefully designed to give favourable flow conditions. The design makes the strainer easy to install, and ensures quick strainer inspection and cleaning. FIA strainers are used ahead of automatic controls, pumps, compressors etc., for initial plant start-up and where permanent filtration of the refrigerant is required.The strainer reduces the risk of undesirable system breakdowns and reduces wear and tear on plant components.

    • KDC pressure control valve
    KDC is a pressure control valve. The valve controls the discharge pressure of the compressor to ensure fast build-up of pressure and lubrication pressure. The valve also acts as a check valve in the discharge line of the compressor.The KDC valve is force-controlled. When pressure in the oil separator is 2 bar (29 psi) higher than the suction pressure, the spring is compressed and the valve opens. In low pressure units (boosters), the spring requires a differential pressure of 0.5 bar (7 psi) for the valve to open.
    Request
    Callback
    Yes! I am interested

    Stop & Regulating Valves

    Stop & Regulating Valves
    • Stop & Regulating Valves
    Get Best Quote
    Stop and regulating valves are manually operated valves for use in industrial refrigeration applications where for instance a pipe section needs to be shut-off during service and maintenance. The valves are in sizes from DN 6 mm (¼ in) up to 300 mm (12 in.). The valves are designed to give favourable flow characteristics and are easy to dismantle for servicing. The valve cone is designed to ensure perfect closing. Applicable to all common refrigerants including ammonia (R717) and non corrosive gases/liquids dependent on sealing material compatibility.
    Product Ranges:

    • SVL multifunction valves
    • SNV-ST / SNV-SS gauge valves
    • SVA-S 6-200 shut-off valves
    • SVA-DL 250-300 shut-off valves
    • QDV shut-off valve
    • REG-SA 10-40 hand operated regulating valve 
    • REG-SB 10-65 hand operated regulating valve 

    Request
    Callback
    Yes! I am interested

    ICF & Valve Stations

    ICF & Valve Stations
    • ICF & Valve Stations
    Get Best Quote
    The ICF control solution can substitute a series of conventional mechanical, electro-mechanical and electronically operated valves, thereby providing a number of advantages in the design phase of a refrigeration plant as well as in the installation, service and maintenance. ICF control solutions consist of valve housing plus a maximum of four or six function modules.

    Models:
    • ICF 15-4 valve station
    • ICF 20-4/ICF 20-6 and ICF 25-4/ICF 25-6 valve station

    The ICF valve station offer savings in time, space and money compared to control solutions using conventional components.

    The ICF valve station incorporates several functions in one control body. An ICF valve station can substitute a series of conventional mechanical, electro-mechanical and electronically operated valves, thereby providing a number of advantages in the design phase of a refrigeration plant as well as in the installation, service and maintenance. ICF valve station consist of a valve housing plus a maximum of four or six function modules.

    The ICF valve stations are designed for low and high pressure refrigerants and can be used in liquid lines, compressor injection lines and hot gas lines.
    The ICF valve stations are supplied as a factory assembly, and are function and pressure tested under factory controlled conditions.
    One code number equals one application solution.

     

    • FA solenoid - retrofit
    The ICF EVRAT retrofit valve incorporates three functions in one housing, which can replace the widely used direct coupled FA EVRAT, as a drop-in solution.

     

    Request
    Callback
    Yes! I am interested

    Solenoid Valves

    Solenoid Valves
    • Solenoid Valves
    Get Best Quote
    Product Ranges:
    • EVRA solenoid valve, servo operated, normally closed (NC)
    EVRA is a direct or servo operated solenoid valve for liquid, suction and hot gas lines with ammonia or fluorinated refrigerants. EVRA valves are supplied complete or as separate components, i.e. valve body, coil and flanges can be ordered separately.

    • EVRAT solenoid valve, assisted lift, normally closed (NC)
    EVRAT is an assisted lift, servo operated solenoid valve for liquid, suction and hot gas lines with ammonia and fluorinated refrigerants.EVRAT is specially designed to open - and stay open - at a pressure drop of 0 bar. The EVRAT solenoid valve is thus suitable for use in all plants where the required opening differential pressure is 0 bar.EVRAT is available as components, i.e. valve body, flanges and coil must be ordered separately. EVRAT 10, 15 and 20 all have spindle for manual operation.

    • ICLX 2-step solenoid valve, one or two step on/off
    ICLX 2-step solenoid valves belong to the Flexline™ range.
    ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas defrost in large industrial refrigeration systems with ammonia, fluorinated refrigerants or CO2.
    The ICLX valve is factory configured to open in 2 steps. By following a simple procedure the valve can be configured to open in 1 step only.
    In 2-step configuration, step 1 opens to approx. 10% of the capacity after the pilot solenoid valves are energized.
    Step 2 opens automatically when the pressure differential across the valve has decreased to approx. 1.5 bar.
    The ICLX 2-step solenoid valve comprises five main components: Valve body, top cover, function module and 2 pilot solenoid valves. On ICLX 32-150 the top cover and function module are factory-assembled.

    • GPLX 2-step solenoid valve, gas powered
    GPLX are 2-step solenoid valves, normally closed (NC). They are designed for hot gas defrosting, liquid lines, suction lines and other applications.The valves have a built-in pressure equalising system preventing pressure shock and therefore eliminating the need for external bypass with resultant cost savings. GPLX are angle valves with weld connections.

    • EVRS / EVRST solenoid valves, stainless steel
    EVRS and EVRST are valves made of stainless steel. EVRS 3 is direct operated, EVRS 10, 15 and 20 are servo operated, EVRST 10,15 and 20 are forced servo operated valves. EVRS and EVRST are used in liquid, suction, hot gas and oil return lines with ammonia or fluorinated refrigerants. EVRS and EVRST are supplied as components, i.e. valve body and coil must be separately ordered. EVRS/EVRST 10, 15 and 20 are equipped with spindle for manual opening.

    • PML/PMLX, pilot valves operated
    PML/PMLX valves are servo-operated main valves with screwed-on pilot solenoid valves. They use an external pressure source for opening, and consequently no differential pressure across the valve is required. PML valves can be used in all types of refrigeration systems, e.g. with direct expansion, pump recirculation or natural circulation, and can be installe in suction lines, return lines (liquid/vapour), pressure-equalizing lines and bypass lines. PMLX valves are used in suction lines for the opening against high differential pressure, e.g. after hot gas defrost in large industrial refrigeration systems. PMLX opens in two steps to avoikd pressure shock in the system.

    • FA solenoid - retrofit
    The ICF EVRAT retrofit valve incorporates three functions in one housing, which can replace the widely used direct coupled FA EVRAT, as a drop-in solution. 
    Request